External (off-chip) Interface
The External DDR interface signals (off-chip) from the DDR PHY to the external memory devices are
shown in Table 2 below.
Signal Name
Bus
Width
Direction Description
4
Output
SDRAM clock signal
4
Output
SDRAM clock signal
4
Output
SDRAM clock enable control signal
4
Output
SDRAM on die termination control signal
1
Output
SDRAM RAS control signal
1
Output
SDRAM CAS control signal
1
Output
SDRAM write enable control signal
1
Output
SDRAM reset signal
16
Output
SDRAM address bus
3
Output
SDRAM bank select
4
Output
SDRAM chip select
9
Output
SDRAM data mask
9
Output
Internal use only. Leave unconnected
72
Inout
SDRAM data bus
9
Inout
SDRAM DQS bus, which is used to clock DQ bus
9
Inout
SDRAM DQS bus, which is used to clock DQ bus
Table-2: PHY/DDR controller to memory interface signals
Parameters
Parameters that can be set for both the DDR controller and PHY are shown in Table 3 below.
Parameter
Default
Value
(hex)
Valid Values Description
DSIZE
72
Multiples of 8 from 8-72
Local side data width
NUM_CLK_OUTS
3
1 to 4
Number of clock outputs
CONTROLLER_REFRESH_EN
1'h1
0-1
Enable controller initiated refreshes.
0: Embedded DDR Controller
automatically handles cyclic
autorefreshing of memory.
1: User manually overrides autorefresh
control of memory.
DELAY_ACTIVATE_TO_PRECHARGE
5'h14
4-30 clock cycles
Minimum ACTIVE to PRECHARGE
DELAY_ACTIVATE_TO_RW
4'h7
2-12 clock cycles
Minimum time between ACTIVATE
and READ/WRITE
DELAY_ACTIVATE_TO_ACTIVATE_DIFF_BANK
3'h4
2-6 clock cycles
Minimum time between ACTIVATE to
ACTIVATE in different banks
DELAY_PRECHARGE_TO_ACTIVATE
4'h7
1-12 clock cycles
Minimum PRECHARGE to
ACTIVATE.
DELAY_ACTIVATE_TO_ACTIVATE_SAME_BANK
6'h20
5-42 clock cycles
Minimum ACTIVATE to
ACTIVATE/AUTO-REFRESH in same
bank
BANK_ACTIVATE_PERIOD
6'h20
7-32 clock cycles
Four bank activate period
DELAY_AUTO_REFRESH_TO_ACTIVATE_SAME_BANK
9'h03B
6-511 clock cylces
Minimum AUTO-REFRESH to
ACTIVATE/AUTO-REFRESH in same
UG031, Nov 18, 2014
11
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 31 32

Comments to this Manuals

No comments

Vertical Communications Auricular inalámbrico teléfono manuales de usuario

Empezando en A

Haga clic en el alfabeto a continuación para desplazarse a la lista completa de modelos que comienzan con esa letra

Modelos Tipo de documento
and FX Series
Manual de usuario   Vertical Communications and FX Series User Manual, 68 paginas
and FXT
Manual de usuario   Vertical Communications and FXT User Manual, 132 paginas